Part Number Hot Search : 
SMDAB RGP10 7011X1 0482223 ON2139 CS42416 TDA73 GPZ20
Product Description
Full Text Search
 

To Download 1991599 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 PM5363 TUPP+622
DATASHEET ERRATA PMC- 1991599 ISSUE 4 SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622MBIT/S INTERFACES
PM5363
TUPP+622
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S INTERFACES
DATA SHEET ERRATA ISSUE 4: JULY 2000
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PM5363 TUPP+622
DATASHEET ERRATA PMC- 1991599 ISSUE 4 SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622MBIT/S INTERFACES
REVISION HISTORY Issue No. 4 Issue Date Jul 2000 Details of Change Removed section on datasheet discrepancies. Removed TU3 Inband Error from the functional discrepancies. Aligns with issue 4 of the datasheet. Aligns with Revision B of the device. Added datasheet discrepancies 2.4-2.8: TUGEN Bit Description, TUGBYP Bit Description, Device ID Revision Number, SOS Bit Description and Boundary Scan ID Change. Removed Issue 2 functional discrepancies 3.1-3.3: Device May Corrupt Data After Reset, Device May Fail to Detect FIFO Over- or Underflow Condition and Device May Fail to Recover From FIFO Over-or-Underflow Condition. Added functional discrepancy 3.2: IAIS Pin Exhibiting Boundary Condition Anomalies Added TU3 Inband Error description. Added changes to timing and operating conditions. All Input Hold Times for SCLK (19.44MHz) are changed from 1ns to 1.5ns. All Output Max Prop Delay for HSCLK (77.76MHz) is changed from 8ns to 9ns. All Output Min Prop Delay for SCLK (19.44MHz) is changed from 2ns to 3.5ns. Operating Condition for VDD3.3 is changed from 3.3V 10% to 3.3V 0.3V and the operating condition for VDD2.5 is changed from 2.5V 10% to 2.5V 0.2V. Document Creation.
3
Jun 2000
2
Feb 2000
1
Nov 1999
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PM5363 TUPP+622
DATASHEET ERRATA PMC- 1991599 ISSUE 4 SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622MBIT/S INTERFACES
CONTENTS 1 ISSUE 4 ERRATA .................................................................................... 2 1.1 2 DEVICE IDENTIFICATION............................................................ 2
FUNCTIONAL DISCREPANCIES ............................................................ 3 2.1 IAIS PIN EXHIBITING BOUNDARY CONDITION ANOMALIES ... 3
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
1
PM5363 TUPP+622
DATASHEET ERRATA PMC- 1991599 ISSUE 4 SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622MBIT/S INTERFACES
1
ISSUE 4 ERRATA This Issue 4 Errata notifies that changes have been made to Issue 4 of the PMC1981421 data sheet. It describes datasheet discrepancies and functional issues in Revision B of TUPP+622, and provides a summary of recommended workarounds. The Issue 4 Datasheet and Issue 4 Errata supersede all prior editions and versions.
1.1
Device Identification The information in this document applies only to the PM5363 TUPP+622 Revision B device. The device revision is marked at the end of the wafer batch code on the face of the device.
Pin A1 Index Mark
PMC Logo TUPP+ Logo
Part Num ber W afe Batch Code Assem bly Date Code Country of Origin TOP VIEW SCALE 1.5:1 (APPROX.)
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
2
PM5363 TUPP+622
DATASHEET ERRATA PMC- 1991599 ISSUE 4 SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622MBIT/S INTERFACES
2 2.1
FUNCTIONAL DISCREPANCIES IAIS Pin Exhibiting Boundary Condition Anomalies
2.1.1 Description The IAIS (IAIS[4:1]) pin is used for tributary AIS insertion when the pointer bypass mode is enabled in the VTPP block (i.e. tributary pointer interpreter is turned off). During the POH or fixed stuff column time-slot, the immediately preceding tributary remains selected. As a result, the corresponding AIS status register maybe updated erroneously if the AIS assertion via the IAIS pin does not persist over the POH or fixed stuff column. 2.1.2 Software Workaround The software workaround is implemented by setting the IPAIS register bit associated with a particular tributary in the VTPP TSB if and when an AIS condition needs to be generated in that tributary. 2.1.3 Hardware Workaround The hardware workaround is implemented by extending or holding the AIS assertion of tributary time-slot immediately preceding the POH or fixed stuff column until the next valid tributary time-slot. The holding period may extend across transport overhead columns of the SONET/SDH frame.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
3
PM5363 TUPP+622
DATASHEET ERRATA PMC- 1991599 ISSUE 4 SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622MBIT/S INTERFACES
CONTACTING PMC-SIERRA, INC. PMC-Sierra, Inc. 105-8555 Baxter Place Burnaby, BC Canada V5A 4V7 Tel: Fax: (604) 415-6000 (604) 415-6200 document@pmc-sierra.com info@pmc-sierra.com apps@pmc-sierra.com (604) 415-4533 http://www.pmc-sierra.com
Document Information: Corporate Information: Application Information: Web Site:
None of the information contained in this document constitutes an express or implied warranty by PMC-Sierra, Inc. as to the sufficiency, fitness or suitability for a particular purpose of any such information or the fitness, or suitability for a particular purpose, merchantability, performance, compatibility with other parts or systems, of any of the products of PMC-Sierra, Inc., or any portion thereof, referred to in this document. PMC-Sierra, Inc. expressly disclaims all representations and warranties of any kind regarding the contents or use of the information, including, but not limited to, express and implied warranties of accuracy, completeness, merchantability, fitness for a particular use, or non-infringement. In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special, incidental or consequential damages, including, but not limited to, lost profits, lost business or lost data resulting from any use of or reliance upon the information, whether or not PMC-Sierra, Inc. has been advised of the possibility of such damage. (c) 2000 PMC-Sierra, Inc. PMC-1991599 (R4) ref PMC- 1981421 (R4) Issue date: July 2000
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE


▲Up To Search▲   

 
Price & Availability of 1991599

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X